Controller Network RS232 and CAN bus Gateway


UIM2513 is an industrial serial port (RS232 protocol) to CAN gateway. Users can send instructions and receive information through UIM2513 to control UIM series servo stepper, AC servo motion controller and I/O controller products.

category:

Gateway Modules

  • Description
  • Product Parameters
  • Quick Connection Diagram
  • Low-profile RS232 and CAN bus System Control Converter Gateway



    UIM2513 is an industrial serial port (RS232 protocol) to CAN gateway. Users can send instructions and receive  information through UIM2513 to control UIM series servo stepper, AC servo motion controller and I/O controller products. Low profile RS232-CAN Control Converter Gateway with wide voltage input 12~48VDC, in an sturdy and durable aluminum case. Robust DSP core and fault tolerance, fail safe user interface, along with free debug/control software and complete SDK, lib, dll and C++, C# example codes. Active CAN 2.0, 1 Mbps Max., with 1500V isolation. Support 3 kinds of CAN IDs: Node ID, Group ID and Global ID. TCP/IP Communication with transformer isolation.

    Connection Port


    Port

    Symbol

    1

    V+

    2

    V-

    3

    CH

    4

    CL



    Features:


    Control System

    • Robust DSP hardware 

    • Fault tolerance, fail safe user interface 

    • Provide complete SDK, lib and DLLs

    • Provide C++, C# sample codes


    RS232 Serial Communication

    • RS232 protocol

    • DB9 Female interface

    • 1500V photoelectric isolation


    CAN Networking

    • Active CAN 2.0, 1 Mbps Max.

    • 1500V photoelectric isolation

    • Support 3 kinds of CAN IDs: Node ID, Group ID and Global ID 


    Other features

    • Wide voltage input 12~48VDC

    • Aluminum alloy casing, sturdy and durable for easy heat dissipation 



    Product Specification:


    name plate.png


  • - Product Parameters:


    Operating Conditions (at ambient temperature 25 °C)

    Supply Voltage (DC)

    12-48 VDC

    Input Current

    0-100 mA

    Operating Environment

    Cooling

    Free Air

    Environment

    Avoid dust, oil mist and corrosive gases

    Operating temperature

    -40℃ ~ 85℃

    Humidity

    < 80% RH, no condensation, no frost

    Vibration

    3 G Max

    Storage-65 ℃ ~ 150 ℃
    Communication Interface

    CAN

    Active CAN 2.0

    CAN Physical

    2 wires, CANH, CANL, twisted pair

    CAN Driver

    Max. 1 Mbps

    Meets ISO-11898 standard physical layer requirements.

    Differential bus

    User InterfaceRS232
    RS232 Physical3 wires,  DB9 Female Connector
    Other
    Dimensions74mm x 38mm x 14mm
    weight 0.15 Kg



  • - Reference Drawings