UIM2502 RS232-CAN Photoelectric Isolation Control Gateway
The UIM2502 RS232-CAN photoelectric isolation control gateway is used in conjunction with UIM242XX stepping motor motion controller.
category:
UIM24XX Series
- Description
- Product Parameters
- Quick Connection Diagram
-
UIM2502 RS232-CAN Photoelectric Isolation Control Gateway
The UIM2502 RS232-CAN photoelectric isolation control gateway is used in conjunction with UIM242XX stepping motor motion controller. With UIM2502, user will be benefited from the advantages of the CAN network and the simplicity of RS232 protocol, and no need to deal with the complicated CAN protocol. With one UIM2502 you can control maximum100 units of UIM242XX through your upper computer. The instruction structure is simple, high fault tolerance. It can be operated by users who know nothing about motor drive or CAN. The enclosure is made of die-cast aluminum which provides a rugged, durable protection and improves the heat dissipation.
Connection Port:
Port
Symbol Description 1
FG
Shielding wire, ground wire (FG) 2
CL
CANL signal lines 3
CH
CANH signal lines 4
0V
Supply voltage ground: 0V
(Positive and negative can not be wrong)
5
V+
Supply voltage, 6-40V Features:
Can2.0 Communication
• Miniature size 66.4mmx38mmx18mm
• Active CAN2.0, one twisted pair for whole netcommunication
• Support 1M bps, long distance (10km)
• Up to 100 nodes can be connected
• Photoelectric Isolation
• Differential data bus, high noise immunity
Motor Driving Characteristics
• RS232 3-wire serial communication
• Max baud rate 115200bps
• Optoelectronic isolation Embedded DSP
Embedded DSP Microprocessor
• Embedded high-performance DSP
• Simple, intuitive, rich commands
• Intelligent, fault-tolerating, user-friendly interface
• MS Windows based VB/VC demo software and corresponding source code provided for free
Electrical Characteristics
• Wide voltage input 6-40VDC
• Max Current 100mA
Product Specification:
-
- Product Parameters:
Electrical Characteristics (TA: 25 ℃)
Supply Power Voltage
6-40VDC
Input Current
Max 100mA
Communication (TA: 25 ℃) Protocol Active CAN 2.0B Wiring method 2-wire, CANH, CANL, twisted pair
CAN bus driver Support 1 Mb/s operation
Short-circuit protection, High voltage
transient protection, Automatic thermal
shutdown protection
Up to 100 nodes can be connected
To User Device RS232 Physical Three-wire: TX, RX, GND RS232 Baud 115200bps Max Baud Rate Set User Instruction Environment Requirements Cooling
Free Air
Environment
Avoid dust, oil mist and corrosive gases
Temperature
-40℃~+85℃
Humidity
<80%RH, no condensation, no frosting
Vibration 3G Max
-
- Reference Drawings: